FHIR © HL7.org  |  Server Home  |  FHIR Server FHIR Server 3.4.11  |  FHIR Version n/a  User: [n/a]

Resource StructureDefinition/FHIR Server from package de.gecco#1.0.5 (78 ms)

Package de.gecco
Type StructureDefinition
Id Id
FHIR Version R4
Source https://simplifier.net/resolve?scope=de.gecco@1.0.5&canonical=https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/sars-cov-2-rt-pcr
Url https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/sars-cov-2-rt-pcr
Version 1.0
Status active
Date 2020-10-29
Name SarsCoV2RTPCR
Title Sars-CoV-2-RT-PCR
Experimental False
Description Qualitative detection of SARS-CoV-2 in respiratory specimens by RT-PCR
Type Observation
Kind resource

Resources that use this resource

No resources found


Resources that this resource uses

StructureDefinition
https://www.medizininformatik-initiative.de/fhir/core/modul-labor/StructureDefinition/ObservationLab MII PR Labor Laboruntersuchung
https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/detected-not-detected-inconclusive Detected Not-detected Inconclusive


Source

{
  "resourceType" : "StructureDefinition",
  "id" : "gecco-observation-sars-cov-2-rt-pcr",
  "url" : "https://www.netzwerk-universitaetsmedizin.de/fhir/StructureDefinition/sars-cov-2-rt-pcr",
  "version" : "1.0",
  "name" : "SarsCoV2RTPCR",
  "title" : "Sars-CoV-2-RT-PCR",
  "status" : "active",
  "date" : "2020-10-29",
  "publisher" : "Charité",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "https://www.bihealth.org/en/research/core-facilities/interoperability/"
        }
      ]
    }
  ],
  "description" : "Qualitative detection of SARS-CoV-2 in respiratory specimens by RT-PCR",
  "fhirVersion" : "4.0.1",
  "kind" : "resource",
  "abstract" : false,
  "type" : "Observation",
  "baseDefinition" : "https://www.medizininformatik-initiative.de/fhir/core/modul-labor/StructureDefinition/ObservationLab",
  "derivation" : "constraint",
  "differential" : {
    "element" : [
      {
        "id" : "Observation.code.coding",
        "path" : "Observation.code.coding",
        "slicing" : {
          "discriminator" : [
            {
              "type" : "pattern",
              "path" : "$this"
            }
          ],
          "rules" : "open"
        },
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc-resp",
        "path" : "Observation.code.coding",
        "sliceName" : "loinc-resp",
        "min" : 1,
        "max" : "1",
        "patternCoding" : {
          "system" : "http://loinc.org",
          "code" : "94500-6"
        },
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc-resp.system",
        "path" : "Observation.code.coding.system",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.code.coding:loinc-resp.code",
        "path" : "Observation.code.coding.code",
        "min" : 1,
        "mustSupport" : true
      },
      {
        "id" : "Observation.subject",
        "path" : "Observation.subject",
        "type" : [
          {
            "code" : "Reference",
            "targetProfile" : [
              "http://hl7.org/fhir/StructureDefinition/Patient",
              "http://hl7.org/fhir/StructureDefinition/Group"
            ]
          }
        ]
      },
      {
        "id" : "Observation.value[x]:valueQuantity",
        "path" : "Observation.value[x]",
        "sliceName" : "valueQuantity",
        "max" : "0"
      },
      {
        "id" : "Observation.value[x]:valueCodeableConcept",
        "path" : "Observation.value[x]",
        "sliceName" : "valueCodeableConcept",
        "min" : 1,
        "binding" : {
          "strength" : "required",
          "valueSet" : "https://www.netzwerk-universitaetsmedizin.de/fhir/ValueSet/detected-not-detected-inconclusive"
        }
      }
    ]
  },
  "text" : {
  }
}